What photoelectric sensor series does DOMENZI offer, and how should I narrow down a model?
DOMENZI photoelectric sensors cover the M18 cylindrical E3F/E3FA family, square heavy-duty E3JK/E3K100, U-slot E3S/GL/PM, background-suppression E3Z, plus CDD all-metal, PCBA board-level modules, XKC-KD200 and fast-door dedicated sensors. Select in four steps: sensing mode (diffuse, retro-reflective, through-beam, slot or BGS), sensing distance, mounting envelope, then supply voltage and output type (DC 10-30 V vs 24-240 V AC/DC, NPN vs PNP). Submitting your operating conditions through the website selection form returns a specific model recommendation.
What do the suffixes N, P, DN, DP, DS, R and -D mean in DOMENZI part numbers?
In DOMENZI part numbers N denotes NPN output and P denotes PNP; DN/DP identify diffuse models; DS pairs with a distance class such as E3F-DS10C4, E3F-DS30C4 or the longer-range DS100C4/DS200C4; R-prefixed codes such as E3F-R2C1 are retro-reflective; on E3K100 the -10M/-20M/-30M suffixes state sensing distance and -D marks a through-beam configuration. Other examples are E3FA-DN50 (50 cm diffuse), E3S-GS30E4 (30 mm slot) and E3K100-10M-D. Always confirm NO/NC contact logic and voltage variants such as -36V against the exact model datasheet before ordering.
型号命名规则NPN PNPE3F-DS30C4E3FA-DN50SKU
03你们是生产厂家还是贸易商?可以验厂或视频验厂吗?
验证 · 品牌与采购主体
是生产厂家,不是贸易商:供货主体为温州东门子科技有限公司,统一社会信用代码 91330303MA285CB24D,成立于 2016-02-26,注册资本壹佰万元整,法定代表人韦永龙,住所浙江省乐清市柳市镇七里村,经营范围包含智能传感器、工控电器与自动化设备的制造、加工、销售及货物与技术进出口。其质量管理体系按 GB/T 19001-2016 / ISO 9001:2015 通过认证(证书号 100126Q00202R001,联铭认证有限公司,CNAS C416-M,2026-08-02 发证,有效至 2029-08-01),认证范围明确包含「资质许可范围内光电开关的制造」。工厂审核或视频验厂可预约安排,并可随批次提供出厂检验记录;审核排期、采用的审核标准(客户自有验厂表或 ISO 9001)与开放区域请在官网提交「供应商审核申请」时注明,由业务书面确认。
EN
Are you a manufacturer or a trading company, and can I arrange a factory audit?
It is a manufacturer, not a trading company. The legal entity is Wenzhou Dongmenzi Technology Co., Ltd., unified social credit code 91330303MA285CB24D, founded 2016-02-26 with registered capital of RMB 1 million, legal representative Wei Yonglong, registered at Qili Village, Liushi Town, Yueqing City, Zhejiang Province. Its business scope covers manufacturing, processing and sales of intelligent sensors, industrial control electrical apparatus and automation equipment plus import/export. Its quality management system is certified to GB/T 19001-2016 / ISO 9001:2015 (certificate 100126Q00202R001, Lianming Certification Co., Ltd., CNAS C416-M, issued 2026-08-02, valid until 2029-08-01), with a scope explicitly including manufacturing of photoelectric switches within the scope of the qualification licence. Factory or video audits can be arranged by appointment and batch inspection records supplied; state the audit standard and areas to be covered in the website supplier-audit request for written confirmation.
What information should I include in an RFQ and how quickly will I get a quotation?
Five items are enough for selection and pricing: sensing mode and distance; target material, colour, size and line speed; supply voltage and output (NPN/PNP, NO/NC); mounting space and connection (1.5 m/2 m cable or M12 connector); and quantity, target lead time and destination. Sales then returns a formal quotation; the response time is confirmed by the website form acknowledgement and the sales confirmation email. A formal quotation should state unit price, MOQ, lead time and validity period.
What is the MOQ for photoelectric sensors, and can I buy a single sample?
Sample and pilot orders are confirmed per model and stock position, while production orders are quoted in quantity tiers; the website does not state one blanket MOQ. Submit a sample or trial-order request on the relevant product page with the model and quantity, and sales will return a formal quotation stating MOQ, unit price and lead time. MOQ discussed verbally is not contractually binding until it appears on that quotation. Common E3FA and E3F variants can normally be validated in a small pilot lot before volume production.
How do I choose between diffuse, retro-reflective and through-beam photoelectric sensors?
Decide by wiring constraints and target properties. Diffuse models (E3F / E3FA-DN) need one-side mounting only and suit opaque targets at 10 cm to 1 m. Retro-reflective models with polarised M.S.R. optics cover 0.1-4 m using one wired side plus an E39-R1 micro-prism reflector, cutting roughly half the cabling versus through-beam. Choose through-beam (separate emitter and receiver) for transparent or highly reflective targets or distances up to 20 m, where the strongest light margin and contamination tolerance are required.
Which sensing distance should I choose, and how do the E3FA 10 cm / 30 cm / 1 m options differ from the E3FA-DN50 50 cm version?
E3FA compact diffuse models come in 100 mm / 300 mm / 1 m versions, E3FA-DN50 is a single 0-50 cm adjustable model, E3F industrial variants adjust 10-50 cm via potentiometer, and E3F-DS100C4 / DS200C4 cover longer classes. Size the working distance at no more than about 70% of the nominal range to absorb losses from target colour, surface finish and lens contamination; models with a large potentiometer allow on-site calibration. For distances beyond 20 m move to E3K100 or E3FA through-beam models.
Which sensor reliably detects clear PET bottles, glass ampoules or transparent film?
Use the P-opaquing transparent-object variant of the E3FA special-reflection series. It analyses birefringent/polarisation attenuation rather than simple reflected intensity, so clear PET bottles, glass ampoules and clear stretch film are detected reliably at 100-500 mm or 0.1-2 m with an E39-R1 reflector. For transparent packaging film or glossy reflective film at close range choose the 10-50 mm limited-distance reflective type; the 30 mm slot of E3S also handles clear sheet material. Standard diffuse sensors let light pass through transparent media and will miss counts.
How do I prevent false triggers from polished stainless steel, reflective conveyors or glossy targets?
Choose the polarised M.S.R. retro-reflective E3FA: its 90-degree polarising filter separates true reflector return from specular reflections off polished stainless steel and glossy film. Alternatively use E3Z background-suppression (BGS) models, which judge distance rather than reflected intensity so black, white and red targets trigger at the same point. E3FA diffuse models add narrow-band optical filters and ambient-light immunity chips to reject intense workshop lighting and flickering fluorescent lamps. Tilting the optical axis slightly away from a mirror surface normal further reduces false switching.
Will sensing distance drift when black, white and red parts run on the same line?
Standard diffuse sensors do show range variation with target reflectance: black parts trigger at a noticeably shorter distance than white ones. For mixed-colour lines requiring a constant switching point, use E3Z background-suppression (BGS) models, rated 100 mm / 200 mm, with a 50 cm adjustable square BGS version also available; E3FA special-reflection BGS variants are likewise colour-independent. During incoming acceptance, verify switching consistency with black, white and red reference parts at the same position.
Which series should I use for sensing distances above 10 metres?
Start with the E3K100 heavy-duty long-range family, offered in 2/5/7/10/15/20/30 m classes with through-beam (-D) and retro-reflective (R) variants, 24-240 V AC/DC wide-range supply and a 3 A 250 VAC relay output. Where mounting space is tight and M18 threading is required, use the E3FA through-beam model (20 m nominal, 15 m option) or the E3FA retro-reflective model (0.1-4 m). Fast-door through-beam sensors cover 0.5-20 m. Always allow alignment margin and use an L-bracket to resist vibration-induced misalignment.
What fits an AGV chassis or robot end-effector where a standard M18 body is too long?
Use the E3FA compact M18 family: the 34.5 mm body is roughly half the length of the older 68 mm housing while retaining standard M18 threading, a large adjustment potentiometer and a 360-degree dual-colour ring indicator, with cable or M12 gold-plated connector options. For even tighter spaces choose the E3Z / E3Z-D61 miniature square housing or PCBA board-level modules (NPN/PNP NO/NC and standalone emitter versions) for direct embedding. Confirm sensing mode, cable exit direction and bracket hole pattern at the same time.
Should I use a slot sensor or a through-beam sensor for elevator levelling and gear speed counting?
A U-slot sensor such as E3S is the first choice: 30 mm slot width and sensing distance, factory-aligned emitter and receiver with no on-site optical alignment, STABILITY (green) and LIGHT (red) indicators, and documentation as an elevator-levelling sensor for high-speed interrupter plates and encoder wheels. GL slot models add 30/50/80/100/120/180/220 mm widths and PM covers miniature slots. Move to E3FA through-beam only when the target span exceeds the slot width or the beam must cross a roller gap.
Which sensor is right for high-speed door and barrier-gate anti-crush protection, and what response time is needed?
Use the fast-door dedicated through-beam or retro-reflective series: DC 12-24 V (ripple below 10%), 0.5-20 m range, detection of opaque objects over 50 mm diameter (people, vehicles, forklifts), visible red beam alignment under 2 degrees, action/reset response at or below 1 ms, IP64/IP67 sealing and immunity up to 3000 lx incandescent and 5000 lx sunlight. For outdoor barriers and car washes, E3K100 offers sub-0.3 ms response and a 3 A relay output. Because anti-crush is a safety-related function, design redundancy and scheduled functional tests to the machine's applicable safety standard.
Which sensor should I use in automatic car washes and high-pressure wash-down bays?
The E3K100 car-wash sensor is designed for it: IP67 with a fully epoxy-potted backplate that withstands high-pressure water and muddy conditions, sub-0.3 ms response, four output configurations (NPN/PNP, NO/NC) in one unit plus a 3 A relay contact, wide 24-240 V DC / 24-240 V AC supply and selectable 2-30 m range. For ordinary wash-down without prolonged immersion, the IP67 fully potted E3FA family is also suitable. Avoid aiming the lens directly at a pressure nozzle and check periodically for scale build-up on the lens.
Which models provide a relay output to drive an AC contactor, alarm lamp or motor directly?
Choose the relay-output E3JK and E3K100 families: their nameplates state 24-240 VAC / 12-240 VDC wide-range input and a 3 A 250 VAC relay contact (E3K100 references JB/T 6475-2019), so they can drive AC loads directly without an interposing relay; E3K100 uses five-wire wiring with brown/blue supply and white/black/grey signal (NO/NC/COM). Standard E3F/E3FA transistor outputs are rated around 200 mA and should feed a PLC input or an external relay, never a motor directly.
主流 M18 系列(E3F / E3FA / E3FA-DN50)为 DC 10–30V 宽压直流,快速门专用型为 DC 12–24V(脉动 <10%),E3S 槽型铭牌为 DC 12–24V,E3JK 为 24–240VAC / 12–240VDC 交直流宽压,E3K100 为 24–240V DC / 24–240V AC(资料另标称 12–240V 通用)。直流晶体管输出型号接错交流市电会损坏,宽压继电器输出型号才可直接用于 AC 220V 控制回路;下单前请按型号规格书核对电压口径。
EN
What are the supply voltage ranges, and what is the difference between DC 10-30 V and 24-240 V AC/DC models?
Mainstream M18 families (E3F / E3FA / E3FA-DN50) run on DC 10-30 V; fast-door dedicated models use DC 12-24 V with ripple under 10%; E3S slot sensors are marked DC 12-24 V. E3JK accepts 24-240 VAC / 12-240 VDC and E3K100 24-240 V DC / 24-240 V AC (some materials state 12-240 V universal). Applying AC mains to a DC transistor-output model will destroy it; only wide-range relay-output models belong in an AC 220 V control circuit. Verify the voltage against the exact model datasheet before ordering.
Should I choose NPN or PNP output, and what should I check when wiring to a PLC?
NPN is sinking (pulls the signal to 0 V when on) and matches sinking-input PLCs common in Japanese systems; PNP is sourcing (delivers +V) and matches sourcing-input PLCs common in European systems. DOMENZI offers both across the range, and the E3K100 car-wash version supports NPN NO/NC and PNP NO/NC in one unit. Confirm whether the PLC input common is tied to 0 V or +V, since a mismatch produces no signal. Standardise on one output type per line and order spares with the matching N or P suffix.
What is the difference between NO and NC, and are they interchangeable within one part number?
NO turns the output on when a target is detected; NC turns it off. Safety-related circuits (anti-crush, anti-pinch, wire-break monitoring) generally use NC because a broken cable is then detectable as a fault. On DOMENZI products NPN/PNP and NO/NC are distinct orderable suffixes - the PCBA modules, for example, are explicitly listed as NPN NO, NPN NC, PNP NO and PNP NC - and cannot be rewired into the opposite logic. State both output type and contact logic on the PO.
What is the output load current, and can 200 mA drive a solenoid or relay coil directly?
E3FA-DN50 is specified at 200 mA load current, a transistor output intended for PLC inputs, optocouplers and small signal loads; it should not directly drive solenoids or contactor coils. Add an interposing relay, or specify E3JK / E3K100 with their 3 A 250 VAC relay output. For inductive loads also allow for inrush and back-EMF and fit a flyback diode or RC snubber at the load. Confirm the rating in the exact model datasheet.
负载电流 200mA晶体管输出感性负载中间继电器
21接线颜色怎么定义?棕、蓝、黑、白、灰分别接什么?
验证 · 电气参数与接线
直流三线/四线制通用定义为棕线接电源正(+V)、蓝线接 0V、黑线为输出信号;E3S 槽型铭牌即标注 Brown 12–24VDC / Blue 0V / Black OUTPUT。E3K100 继电器输出为五线制:棕/蓝为供电,白/黑/灰为 NO / NC / COM 信号端。E3FA-DN50 另标注尾部 360° 双色 LED(绿色电源常亮、橙色动作触发)。不同系列线序可能不同,接线前必须以随机接线图或机身铭牌为准,严禁仅凭颜色类推。
EN
What is the wire colour code - brown, blue, black, white and grey?
For DC three-/four-wire sensors the usual convention is brown = +V, blue = 0 V, black = output; the E3S nameplate reads Brown 12-24 VDC / Blue 0 V / Black OUTPUT. The E3K100 relay version uses five wires: brown/blue for supply and white/black/grey for NO / NC / COM contacts. E3FA-DN50 adds a 360-degree dual-colour LED (green power, orange action). Wire assignments can differ between families, so always follow the supplied wiring diagram or the nameplate rather than generalising from colour.
Is an M12 connector version available, and can cable length be customised?
The E3FA compact family offers both cable-exit and M12 gold-plated connector versions; the E3FA through-beam model is specified with a 2 m flexible cable or an M12 connector, E3FA-DN50 ships with a 1.5 m cable, and E3F uses an integrally moulded sealed cable exit. Custom cable length, gauge, connector brand and pin-out are negotiable order options that must be documented in a written technical agreement and reflected in the part-number suffix. Fully potted cable-exit models cannot be rewired on site without destroying the IP67 seal. Submit a customisation request form to confirm the available range.
Do the sensors have short-circuit, reverse-polarity and surge protection, and will a wiring mistake destroy them?
E3F industrial and E3FA compact diffuse models are specified with built-in short-circuit, reverse-polarity and surge protection, plus internal EMC shielding against VFD motors and welding equipment. Protection does not cover connecting the wrong supply class: applying AC 220 V to a DC 10-30 V transistor model will still destroy it and is not a warranty case. Check supply voltage and polarity with a multimeter before energising and add a fuse or current limiting on the machine side.
What is the difference between IP67 and IP68, and which rating do your sensors actually carry?
IP67 is the mainstream rating across DOMENZI sensors (E3FA, E3F industrial, E3K100, E3S), with fast-door models listed as IP64/IP67; only the E3F industrial enhanced variant is described in marketing material as IP67/IP68. IP67 covers temporary immersion, IP68 continuous immersion under manufacturer-declared conditions, and neither implies the other. Verifiable documentary evidence: CCC certificate 2024010305709897 (China Quality Certification Centre, valid until 2029-10-31) states IP65 for the D-□-18□Y□ AC models it covers, while the 45-page GTS Technical Construction File TLZJ25093076489 (2025-09-30) lists series ratings of IP65 / IP67 / IP68 / IP69. These are different models and different conventions, so the website states the rating per model rather than claiming IP68 across the range, and does not treat a declared rating as an IEC 60529 test result. For marine, permanent immersion or high-pressure wash-down duty, request the IEC 60529 ingress test report for the exact model before ordering.
What practical benefit does full epoxy potting provide inside the sensor?
E3F industrial, E3FA and E3K100 models use solid or vacuum epoxy potting that seals the PCB against moisture, dust, oil and condensation and locks components against vibration and shock - the structural basis of their IP67 rating and wash-down reliability. For a buyer this means fewer water-ingress failures and intermittent false triggers in wash-down zones, humid plants and outdoor equipment, with lower maintenance and downtime. The trade-off is that a potted unit cannot be repaired or rewired on site, so cable length, exit direction and connector must be fixed at order time.
Will direct sunlight, halogen lamps or flickering fluorescent lighting cause false switching, and what are the ambient-light limits?
E3FA diffuse models use narrow-band optical filters and dedicated anti-interference chips and are specified to operate without false triggers under intense workshop lighting in the tens of thousands of lux; fast-door dedicated sensors give explicit limits of 3000 lx incandescent and 5000 lx sunlight; E3K100 uses a thick flame-retardant red housing rated for heat and UV ageing. For outdoor or high-glare stations prefer visible-red through-beam or retro-reflective models for easy alignment and add a light shield against direct sun. Validate ambient-light immunity on site at the actual illuminance during acceptance.
Will VFDs, welding machines or large motors cause false triggering?
E3FA through-beam models specify a sealed shielding layer against strong electromagnetic interference from three-phase VFD motors and welders; E3S slot sensors explicitly add an internal shield for improved VFD immunity plus a STABILITY indicator for on-site diagnosis; E3F industrial models include EMC shielding and anti-interference circuitry. As good practice, route sensor signal cable separately from power cable in divided trunking, ground the shield at one end only, and feed the sensor from a supply separate to the VFD input side.
What is the response time, and will high-speed production lines suffer missed detections?
By family: E3F industrial is specified at 1 ms or less and demonstrated at 300 pcs/min with clean square-wave pulses; E3K100 car-wash models are under 0.3 ms; fast-door models are 1 ms or less action/reset (0.02 s response); E3S slot sensors suit high-speed encoder wheels and elevator levelling. Missed counts also depend on PLC input filter time and the minimum beam-interruption width of the part, so ensure beam-break duration exceeds sensor response plus PLC input delay and verify count accuracy at maximum line speed during acceptance.
What are the operating temperature, vibration and chemical-resistance limits?
The current product materials do not state a single operating temperature range or quantified vibration/chemical limits, so these must be confirmed from the datasheet for the specific model. Confirmed construction details are: rigid ABS or flame-retardant engineering housings with full potting on E3FA/E3K100, M18x1 nickel-plated brass or reinforced polymer on E3F industrial, all-metal construction on CDD, and nickel-plated copper housing with die-cast lens on fast-door models. For high or sub-zero temperatures, salt spray, cutting fluid or aggressive cleaning agents, list the temperature profile and media in the RFQ so engineering can confirm material compatibility in writing.
四类都有可核验的原件,但适用范围不同,不能笼统说「齐全」。① CCC:中国国家强制性产品认证证书 2024010305709897(中国质量认证中心有限公司 CQC,2024-11-01 发证,有效至 2029-10-31),覆盖光电开关 D-□-18□Y□ 系列,依据 GB/T 14048.10-2016,标注 Ue AC90-250V、Ie 0.3A、IP65;并不覆盖全部型号。② ISO 9001:质量管理体系认证证书 100126Q00202R001(联铭认证有限公司,IAF / CNAS C416-M,有效至 2029-08-01),标准 GB/T 19001-2016 / ISO 9001:2015,范围含「资质许可范围内光电开关的制造」,认证的是工厂体系而非单个产品。③ 欧盟 CE/LVD:GTS 出具的 Verification of LVD Compliance,编号 CLZJ23122253710(报告 TLZJ23122253710,2023-12-26,有效至 2028-12-25),依据 EN IEC 60947-1:2021、EN IEC 60947-5-2:2020 与 LVD 2014/35/EU,型号清单覆盖 E3F/E3FA/E3JK/E3K100/E3Z/E3S/GL/PM/CDD 等系列;CE 标志由制造商在完成 EU 符合性声明后自行加贴,该验证文件不是「CE 证书」。④ RoHS:ZRC 出具 Certificate of Compliance ZRC2608545XY-C0317 与报告 ZRC2608545XY-R0317(2026-08-31),依据 EN 62321 系列、EN IEC 63000:2018 及 (EU) 2015/863、2011/65/EU 附录 II,属自愿性符合性文件,不代表公告机构合格评定。另有两张防爆合格证(C LEx23.8351、C LEx26.7747X),仅覆盖防爆接近开关/本安型传感器,不属于光电开关系列。下单前请按「型号—证书编号—有效期—适用地区」四项核对,不要以宣传图上的徽章代替证书。
EN
Which certificates do DOMENZI sensors carry - CE, RoHS, CCC and ISO 9001?
All four exist as verifiable originals, but their scopes differ, so a blanket yes would be misleading. (1) CCC: China Compulsory Certification certificate 2024010305709897 (China Quality Certification Centre Co., Ltd., issued 2024-11-01, valid until 2029-10-31) covers the D-□-18□Y□ photoelectric switch series to GB/T 14048.10-2016, stating Ue AC90-250 V, Ie 0.3 A and IP65; it does not cover every model. (2) ISO 9001: quality management system certificate 100126Q00202R001 (Lianming Certification Co., Ltd., IAF / CNAS C416-M, valid until 2029-08-01) to GB/T 19001-2016 / ISO 9001:2015, with a scope including manufacturing of photoelectric switches within the qualification licence - it certifies the factory system, not one product. (3) EU CE/LVD: GTS Verification of LVD Compliance CLZJ23122253710 (test report TLZJ23122253710, 2023-12-26, valid until 2028-12-25) to EN IEC 60947-1:2021 and EN IEC 60947-5-2:2020 under LVD 2014/35/EU, covering E3F/E3FA/E3JK/E3K100/E3Z/E3S/GL/PM/CDD and other series; the CE mark is affixed by the manufacturer after completing an EU Declaration of Conformity, so this verification is not a CE certificate. (4) RoHS: ZRC Certificate of Compliance ZRC2608545XY-C0317 with report ZRC2608545XY-R0317 (2026-08-31), to the EN 62321 series, EN IEC 63000:2018, (EU) 2015/863 and Annex II of 2011/65/EU - a voluntary document, not a Notified Body assessment. Two explosion-protection certificates (C LEx23.8351 and C LEx26.7747X) cover explosion-proof proximity switches / intrinsically safe sensors only, not photoelectric switches. Before issuing a PO, check model, certificate number, validity and target market for each document instead of relying on marketing badges.
Can you supply a CE Declaration of Conformity, RoHS report and third-party test reports?
Yes, and the documents can be checked by number. (1) EU LVD: GTS Verification of LVD Compliance CLZJ23122253710 (test report TLZJ23122253710, valid until 2028-12-25) plus the 45-page Technical Construction File TLZJ25093076489 (2025-09-30, EN IEC 60947-1:2021 and EN IEC 60947-5-2:2020+A11:2022); the EU Declaration of Conformity is signed by the manufacturer and supplied with the order, and a third-party verification cannot replace it. (2) RoHS: Certificate of Compliance ZRC2608545XY-C0317 and the 11-page test report ZRC2608545XY-R0317 (ZRC International Testing (Shenzhen) Co., Ltd, 2026-08-31). (3) China CCC: certificate 2024010305709897 (CQC, valid until 2029-10-31). (4) Quality system: ISO 9001 certificate 100126Q00202R001 (valid until 2029-08-01). (5) Explosion protection: C LEx23.8351 and C LEx26.7747X, limited to explosion-proof proximity switches / intrinsically safe sensors. Third-party reports must name the issuing laboratory, report number, test standard and the exact sample model, which has to match the purchased part number; marketing imagery and video scripts are not compliance documents. A standalone EMC test report, REACH/UKCA/UL documents and an IEC 60529 immersion test report are not present in the current set and must be confirmed per project. State the intended use (customs clearance, customer audit or tender) in the RFQ so a stamped set can be prepared in one pass.
CE DoCRoHS ZRC2608545XY-C0317TCF TLZJ25093076489CCC 2024010305709897第三方检测报告清关文件
Is there a third-party IP67/IP68 test report, and how do I verify it?
What is available today is third-party technical documentation, not a standalone IEC 60529 immersion test report. The first page of the 45-page GTS Technical Construction File (TCF, report TLZJ25093076489, 2025-09-30, reviewed by Shanghai GTS) lists series ingress ratings of IP65 / IP67 / IP68 / IP69; CCC certificate 2024010305709897 (valid until 2029-10-31) states IP65 for the D-□-18□Y□ AC models it covers; the ZRC RoHS report ZRC2608545XY-R0317 (2026-08-31) does not address ingress protection. The website therefore states IP67 as the mainstream rating, does not claim IP68 across the range, and does not treat a declared rating as a test result. To verify IP67/IP68, request an IEC 60529 report and check four points: whether the sample model matches the purchased part number, immersion depth and duration, post-test functional verification, and the report number with issuing laboratory. For an IP68 claim, confirm the manufacturer-specified conditions in particular. For marine, permanently submerged or high-pressure wash-down use, add sample immersion retesting to incoming inspection.
What outgoing QC checks are performed, and can I get an inspection report with batch traceability?
The factory quality management system is certified to GB/T 19001-2016 / ISO 9001:2015 (certificate 100126Q00202R001, Lianming Certification Co., Ltd., valid until 2029-08-01, scope including manufacturing of photoelectric switches within the qualification licence), and outgoing inspection follows that system. Specify in the contract that inspection covers at minimum visual and nameplate model verification, powered tests of supply voltage and output logic (NPN/PNP, NO/NC), sensing-distance and indicator checks, plus sample insulation-resistance and seal-integrity tests. The batch number should trace back to the production date and inspection records for warranty handling. The current materials do not state an AQL level or inspection form number, so request the outgoing-inspection procedure plus a recent batch report sample and attach them to the quality agreement.
What compliance documents are needed for export to the EU, North America or other regions, including REACH and UKCA?
For the EU, verifiable documents exist: LVD Verification CLZJ23122253710 (GTS, valid until 2028-12-25, to 2014/35/EU and EN IEC 60947-1:2021 / 60947-5-2:2020), the 45-page Technical Construction File TLZJ25093076489, RoHS 2.0 Certificate of Compliance ZRC2608545XY-C0317 with test report ZRC2608545XY-R0317 (2026-08-31, to (EU) 2015/863 and Annex II of 2011/65/EU), plus a manufacturer-signed EU Declaration of Conformity. Domestic Chinese sales additionally involve CCC certificate 2024010305709897 (limited to D-□-18□Y□ models, valid until 2029-10-31). No REACH SVHC declaration, UKCA, UL or FCC certificate, nor a standalone EMC test report, is present in the current set, so the website does not claim them by default; the UK and North American markets require confirmation per model and destination. State the destination country, intended use and required documents (customs clearance, tender or customer audit) in the RFQ so compliance can issue the correct list; packing list, commercial invoice, certificate of origin and material/packaging declarations are supplied per order. Note also that the English entity name appears as both Dongmenzi and Domenzi on different certificates - the applicant and manufacturer names on export documents must match the contracting entity.
When specs differ between pages or documents, which value takes precedence?
The authoritative set is the latest model-specific datasheet, the physical nameplate, and the confirmed written quotation or technical agreement, in that order; videos, hero images and detail-page graphics are selection aids only. The source material contains variations - E3K100 supply is stated both as 24-240 V and nominally 12-240 V, the E3F industrial model lists IP67/IP68 side by side, and fast-door response appears as both 0.02 s and 1 ms or less. Certificate data also has to be read per model: CCC certificate 2024010305709897 states IP65 for the D-□-18□Y□ AC models, E3FA and other DC models are documented as IP67, and the GTS Technical Construction File TLZJ25093076489 lists series ratings of IP65/IP67/IP68/IP69. These are different models and different documentary conventions rather than contradictory values for one part. Send the model plus the disputed parameter to engineering for written clarification before ordering and attach that clarification to the contract to avoid acceptance disputes.
How is pricing calculated, and are volume tiers or annual price locks available?
Unit price is built from model, output type, sensing distance, connection style and quantity; NPN vs PNP, NO vs NC, cable vs M12 and custom cable length are separate SKUs, so an RFQ must carry the complete part-number suffix. Volume orders are quoted in quantity tiers and annual framework agreements can define a price-lock period and adjustment mechanism. The current materials contain no photoelectric sensor price list or discount bands and the website does not publish unconfirmed figures; rely on the formal quotation stating currency and validity.
Are prices tax-inclusive, and can you issue a VAT invoice?
Tax inclusion, the applicable rate and invoice type must be stated line by line on the formal quotation, with domestic tax-inclusive pricing distinguished from export tax-exclusive pricing. The entity issuing a VAT special invoice, the invoice description and the timing should match the contracting entity. Cross-border orders additionally need clarity on the declarant, export rebate ownership and currency/FX basis. The source materials contain no tax terms, so the website makes no default commitment; specify tax-inclusive or exclusive pricing, invoice type and billing details in the RFQ for written confirmation.
含税价增值税专用发票出口退税开票主体
38支持哪些付款方式?可以用贸易保证 / 信用证吗?
下单 · 报价、订单与交付
常见可协商方式包括电汇(T/T,含预付与尾款比例)、平台贸易保证订单、以及大额订单的信用证(L/C);首单与样品单通常采用预付,长期合作客户可申请账期。付款节点、账期、保证金比例与汇率基准应写入合同或形式发票(PI),并与报价单主体一致。跨境支付还需确认收款账户名与合同主体一致,避免第三方收款风险。具体可用方式请由业务在 PI 中书面确认。
EN
What payment terms are supported, including Trade Assurance or letter of credit?
Negotiable terms typically include T/T with agreed deposit and balance, platform Trade Assurance orders, and L/C for larger contracts; first orders and samples are usually prepaid while established accounts may qualify for credit terms. Payment milestones, credit period, deposit ratio and FX basis belong in the contract or proforma invoice and must reference the same legal entity as the quotation. For cross-border payment verify that the beneficiary name matches the contracting entity to avoid third-party collection risk. Sales will confirm the available options in writing on the PI.
What is the lead time, and are common models kept in stock?
Lead time depends on three factors: whether the model is a stocked standard, the quantity, and any customisation. Common standard suffixes in the E3F/E3FA families can generally be dispatched sooner, while custom cable lengths, private labelling, special output logic or non-standard distance classes add sampling and production time; volume orders also need incoming inspection and shipping windows. The source materials give no stock levels or standard lead-time days, so the website states no blanket figure. Put your required delivery date in the RFQ and have sales specify production time, shipping time and the lead-time start point on the quotation.
Who pays freight, customs and duties, and which Incoterms are supported?
Cost and responsibility follow the agreed Incoterms rule (for example EXW / FOB / CIF / DDP), which must be stated with its version and named place on both quotation and contract, such as FOB Ningbo or DDP customer warehouse. Because photoelectric sensors are small and light, freight, duties and inspection often dominate total cost on volume orders, so compare landed unit cost rather than ex-works price alone. The materials contain no logistics terms; state the destination port/place and preferred Incoterm in the RFQ so sales can return a quote with freight and insurance broken out.
Can we sign an annual framework agreement or arrange consignment stock?
Long-term cooperation can be structured under an annual framework agreement covering rolling forecasts, a price-lock period, scheduled call-offs, safety or consignment stock, and a product-change notification (PCN) obligation. For OEM machine builders, freeze the output type, cable length and potting configuration of critical models as controlled specifications, with advance written notice and sample re-approval for any change. Consignment eligibility, minimum annual volume and stock ownership are subject to supply-chain review and must be written into the agreement; the website makes no default commitment.
How should I run incoming inspection on a volume delivery, and what should I sample-test?
Use five steps: document check, visual and nameplate check, powered function test, distance/immunity sampling, and seal sampling. Verify the model suffix, quantity, batch number and inspection report; power up to confirm supply voltage, NPN/PNP and NO/NC logic and dual-colour LED behaviour; test switching consistency with black and white reference parts at roughly 70% of nominal range; and sample immersion or spray retest batches claimed as IP67. If a parameter deviates from the datasheet, retain the sample and batch photos and raise a written claim under the contract quality clause.
Which parameters must the purchase contract or technical agreement fix to avoid shipping the wrong part?
Lock at least ten items: complete part number including suffix; sensing mode and nominal distance; supply voltage and allowable ripple; NPN/PNP output and NO/NC logic; load current or relay contact rating; connection type, cable length and wire assignment; ingress rating and the required test report; housing/lens material and colour; operating temperature and ambient-light/EMC conditions; and the compliance document set, packaging and labelling. Add an attachment stating that the latest datasheet governs and defining a written clarification process for conflicting values to reduce mis-shipments and acceptance disputes.
采购合同技术协议参数冻结错发货验收争议
G 样品、定制与包装物流 Samples, OEM & Logistics · 4 问
44样品怎么申请?样品费、运费怎么算,能抵扣货款吗?
下单 · 样品、定制与包装物流
在对应产品页提交「样品申请」并写明完整型号、数量、收货地址与拟验证的工况,建议同时申请 2–3 只以便做一致性与安装对比。样品通常按样品价加运费结算,是否可在后续量产订单中抵扣、抵扣比例与有效期由业务在样品单中书面确认。样品到手后建议按 FAQ 42 的来料检验流程做通电与距离实测,并把验证结果作为量产 PO 的附件。
EN
How do I request samples, and are sample fees or freight refundable against a production order?
Submit a sample request on the relevant product page with the complete part number, quantity, delivery address and the conditions you intend to validate; two or three units are recommended for consistency and mounting comparison. Samples are normally charged at a sample price plus freight, and whether that cost can be credited against a later production order, the credit ratio and its validity are confirmed in writing on the sample order. On arrival, run the powered and distance checks described in FAQ 42 and attach the results to the production PO.
Do you support OEM/ODM, customer logo printing and non-standard customisation?
The source set already shows derived and custom variants - an E3F custom edition, the CDD all-metal version, PCBA board-level modules including a standalone emitter and four output combinations, multiple E3K100 distance SKUs, and cable/M12 options - indicating experience with model derivatives and structural customisation. Negotiable scope typically covers logo and nameplate printing, cable length and connector, output type, distance class, housing colour and packaging, subject to MOQ, tooling or certification impact and lead time. Submit a customisation request form for engineering feasibility and a written quotation, and re-approve a sample before volume production of any custom part number.
OEM ODM丝印 LOGO定制线长PCBA 模块定制需求表
46包装规格、最小包装数和外箱唛头怎么定?
下单 · 样品、定制与包装物流
光电开关属于小型精密器件,建议合同明确:单只独立袋/盒防护、防静电与缓冲要求、每内盒与每外箱数量、外箱尺寸与毛重、唛头内容(品名、型号、数量、批次号、毛净重、目的地与易碎/防潮标识),以及出口订单的托盘与缠膜要求。现有素材未给出统一包装规格与箱规,官网不默认承诺;请在 PO 前索取「包装规范书 + 装箱单样本」,并把唛头图稿作为合同附件确认。
EN
How are packaging, inner pack quantity and carton marks defined?
As small precision devices, sensors should have a contract-defined pack: individual bag or box protection, anti-static and cushioning requirements, units per inner box and outer carton, carton dimensions and gross weight, shipping mark content (description, model, quantity, batch number, gross/net weight, destination and fragile/keep-dry symbols), plus palletising and wrapping for export. The source materials give no standard pack specification or carton count, so the website makes no default commitment. Request the packaging specification and a sample packing list before the PO and attach the approved mark artwork to the contract.
Do you support neutral packaging, customer labelling or drop-shipping?
Neutral packaging, customer label application and split or drop shipments are negotiable fulfilment services that must be defined in the order: whether brand marks are removed, label artwork and barcode rules, ship-to addresses and batch-splitting rules, and any packaging or documentation charges. Where brand identification changes, note that the DOMENZI device mark is a registered Class 9 trademark in China (registration No. 19966152, holder Wenzhou Dongmenzi Technology Co., Ltd., renewal valid until 2037-07-06), so also confirm trademark and compliance requirements in the destination country to avoid customs or customer-audit issues. Sales will confirm the available scope, minimum conditions and costs in writing on the quotation or fulfilment agreement.
中性包装贴标条码一件代发商标注册号 19966152履约协议
H 质保与技术支持 Warranty & Support · 3 问
48质保期多久?哪些情况不在质保范围内?
售后 · 质保与技术支持
DOMENZI 产品主图与宣传资料统一标注「质保 365 天」(365 Days Warranty)。质保通常覆盖正常使用下的材料与制造缺陷;接错电源制式(如 DC 型号接入 AC 220V)、超出负载电流直接驱动感性负载、擅自拆解灌封机身或换线造成密封破坏、高压水枪直冲透镜、以及未按接线图施工导致的损坏,一般不属质保范围。质保起算点(出厂日 / 到货日 / 验收日)、换新或维修方式与跨境运费承担,请以官网质保条款和订单书面约定为准,并在合同附件中写明。
EN
How long is the warranty, and what is excluded?
DOMENZI product imagery and video materials consistently state a 365-day warranty. Coverage normally applies to material and manufacturing defects under normal use. Typical exclusions include applying the wrong supply class (AC 220 V to a DC model), exceeding the load current or driving inductive loads directly, opening the potted housing or rewiring and thereby breaking the IP seal, directing a pressure washer at the lens, and damage from wiring that ignores the supplied diagram. The warranty start point (ship date, arrival date or acceptance date), replacement versus repair, and cross-border freight responsibility are governed by the website warranty terms and the written order; state them in the contract attachment.
质保365天365 Days Warranty质保范围除外责任
49到货后发现型号发错、数量短缺或运输损坏,怎么处理?
售后 · 质保与技术支持
请在收货后按合同约定的异议期(建议写明到货后 X 个工作日内)提出书面异议,并保留外箱照片、唛头、装箱单、批次号与不良样品,不要先拆封或自行返修。核对型号后缀与数量后,由售后按合同判定补发、换货或退款;运输损坏需同时提供承运人签收异常记录以便索赔。跨境订单建议约定检验窗口、索赔单证清单与补件出运方式,避免超过平台或保险索赔时效。
EN
What should I do if the wrong model arrives, quantities are short or the shipment is damaged?
Raise a written claim within the contractual objection period (state a defined number of working days after arrival) and preserve carton photos, shipping marks, packing list, batch number and the defective samples; do not unpack everything or attempt self-repair first. After the model suffix and quantity are reconciled, after-sales determines replacement, exchange or refund under the contract; transit damage also requires the carrier's delivery exception note for the claim. For cross-border orders, agree the inspection window, claim document list and replacement shipping method to avoid missing platform or insurance deadlines.
Do you provide selection, commissioning and troubleshooting support?
Support covers selection, installation and fault finding: submit target material/colour/size, line speed, mounting space, supply voltage and PLC input type for an engineering model recommendation; during commissioning get help with beam alignment, potentiometer calibration, NPN/PNP wiring checks and EMC cable-routing advice; for field faults follow the sequence supply and polarity, indicator status, output logic, distance and background, then ambient light/EMC. Keep the datasheet, wiring diagram and batch number with the goods for remote diagnosis. Channels, response times and on-site service availability are defined on the website Technical Support page and the service agreement.